Control Syringe
Code |
84001 |
Showing 17–30 of 30 results
These cannulae feature kink resistant, wirewound bodies with beveled metal, multi-port tips. This construction allows for higher flow rates with minimal pressure differential. A tip orientation line permits precise positioning of the cannulae.
Code |
Specification |
326112 |
12Fr |
326114 |
14Fr |
326116 |
16Fr |
326118 |
18Fr |
326120 |
20Fr |
326122 |
22Fr |
326124 |
24Fr |
326126 |
26Fr |
326128 |
28Fr |
326130 |
30Fr |
These cannula feature beveled, thin wall tips with elongated, one piece, kink resistant wire reinforced bodies. This construction allows for higher flow rates with minimal pressure differential. Anintroducer along with depth markings permit precise positioning of the cannula.
Vented |
Non-vented |
|
|
Code |
Code |
Specification |
|
3431108 |
3431208 |
8Fr |
|
3431110 |
3431210 |
10Fr |
|
3431112 |
3431212 |
12Fr |
|
3431114 |
3431214 |
14Fr |
|
3431116 |
3431216 |
16Fr |
|
3431118 |
3431218 |
18Fr |
One piece body. Straight or Curved tip, available with connector acceptance, vented connector or non-vented connector. An adjustable or fixed depth ring together with tip and depth line permits precise position of all cannula.
Pediatric – 20cmlength |
||
Straight Tip |
Curved Tip |
|
Code |
Code |
Specification |
3421110 |
3422110 |
10Fr |
3421112 |
3422112 |
12Fr |
3421114 |
3422114 |
14Fr |
3421116 |
3422116 |
16Fr |
3421118 |
3422118 |
18Fr |
Adult – 20cm length |
||
3421120 |
3422120 |
20Fr |
3421122 |
3422122 |
22Fr |
3421124 |
3422124 |
24Fr |
3421126 |
3422126 |
26Fr |
Injected Tip, Straight or Curved tip, available with connector acceptance, vented connector or non-vented connector. A fixed ring with tip and depth line permits precise position of cannula.
Pediatric – 20cm length |
|
||
Straight Tip |
Curved Tip |
|
|
Code |
Code |
Specification |
|
3421212 |
3422212 |
12Fr |
|
3421214 |
3422214 |
14Fr |
|
3421216 |
3422216 |
16Fr |
|
3421218 |
3422218 |
18Fr |
|
Adult – 20cm length |
|||
3421220 |
3422220 |
20Fr |
|
3421222 |
3422222 |
22Fr |
|
3421224 |
3422224 |
24Fr |
|
3421226 |
3422226 |
26Fr |
Connect and help to measure the pumping pressure and cardiac arrest perfusion pressure. Transfer pressure to prevent the blood flow into the pressure measurement device.
Transfer scope: 20-50Kpa
Conductivity≧85%
(Clean PC, Disposable)
Code |
Specification |
2401 |
Half Volume |
2402 |
Full Volume |
It’s a blood channel during cardiac operation.
Adult: Recommended for body weight over 35kg
Pediatric: Recommended for body weight between20-35kg
Infant: Recommended for body weight below 20kg.
Code |
Specification |
|
2101 |
Adult |
|
2102 |
Pediatric |
|
2103 |
Infant |
|
|
Note: We can produce different design of tubing pack according to customer’s drawing.
In cardiac operation, the cannula is inserted in root of aorta through which cold arrest liquid is perfused.
(Standard type)
With Suture Flange, a stainless steel introducer needle, clean body.
Code |
Specification |
Length |
|
35101 |
Adult |
155mm |
|
35102 |
Pediatric |
150mm |
|
35103 |
Infant |
100mm |
|
35104 |
Adult-Long |
350mm |
|
35105 |
Adult-Long |
250mm |
(Vent Line type)
With Suture Flange, a stainless steel introducer needle, clean body. With vent line
w/ normal tube |
||
Code |
Specification |
Vent Line Position |
35201 |
Adult |
Patient End |
35202 |
Pediatric |
Patient End |
35203 |
Adult |
Machine End |
35204 |
Pediatric |
Machine End |
(New Vent Line type)
With Suture Flange,a stainless steel introducer needle,clean body.Special vent line far away from tip supplies good operation view for doctor.
w/ normal tube |
|
Code |
Specification |
35301 |
12G |
35302 |
14G |
One piece and wire reinforced body. Straight or Curved tip, available with connector acceptance, vented connector or non-vented connector. A fixed ring with tip and depth line permits precise position of cannula.
Pediatric – 21cm length |
|
||
Straight Tip |
Curved Tip |
|
|
Code |
Code |
Specification |
|
3413116 |
3414116 |
16Fr |
|
3413118 |
3414118 |
18Fr |
|
Adult – 24cm length |
|||
3413120 |
3414120 |
20Fr |
|
3413122 |
3414122 |
22Fr |
|
3413124 |
3414124 |
24Fr |
Injected Tip, Straight or Curved tip, available with connector acceptance, vented connector or non-vented connector. A fixed ring with tip and depth line permits precise position of cannula.
Pediatric – 20cm length |
|
||
Straight Tip |
Curved Tip |
|
|
Code |
Code |
Specification |
|
3411212 |
3412112 |
12Fr |
|
3411214 |
3412114 |
14Fr |
|
3411216 |
3412116 |
16Fr |
|
3411218 |
3412118 |
18Fr |
|
Adult – 20cm length |
|||
3411220 |
3412120 |
20Fr |
|
3411222 |
3412122 |
22Fr |
|
3411224 |
3412124 |
24Fr |
|
3411226 |
3412126 |
26Fr |
In cardiac operation, through it the cold arrest liquid is perfused.
Motel: B-Ⅰand B-Ⅱ
B-I applies to where need perfuse mixed cardioplegic solution of crystalloid and oxygenated blood.
B-Ⅱapplies to where need crystalloid cardioplegic solution
Code |
Specification |
2201 |
Crystalloid |
2202 |
Blood |
2203 |
Customized |
Note: We can produce different design of tubing pack according to customer’s drawing.
Use to carry on precava and postcava incubation when doing open heart surgery
There are reinforced stainless lines within tubing wall to prevent bending. Transparent and smooth tubing with porous structure of injection side.
Match with Guide wire within the inner lumen of cannula.
Two models: One Stage Venous Cannula and Two Stage Venous Cannula.
One piece body. Wire Reinforced wall.
Normal Body |
Oval Body |
|
|
Code |
Code |
Specification |
|
321214 |
323214 |
14Fr |
|
321216 |
323216 |
16Fr |
|
321218 |
323218 |
18Fr |
|
321220 |
323220 |
20Fr |
|
321222 |
323222 |
22Fr |
|
321224 |
323224 |
24Fr |
|
321226 |
323226 |
26Fr |
|
321228 |
323228 |
28Fr |
|
321230 |
323230 |
30Fr |
|
321232 |
323232 |
32Fr |
|
321234 |
323234 |
34Fr |
|
321236 |
323236 |
36Fr |
|
321238 |
323238 |
38Fr |
Use to filtering the particles, such as blood clots, fragments and aeroembolisms when doing the open heart surgery.
High transparency PC housing.
40 μm Polyester
Four models: Adult, Pediatric, Infant and neonate
Code |
Specification |
Maximum Flow rate(L/min) |
Filtrate area (cm2) |
Filtrate size(μm) |
Priming volume(mL) |
|
2211 |
Adult |
7.0 |
600 |
40 |
160 |
|
2212 |
Pediatric |
3.0 |
300 |
40 |
100 |
|
2213 |
Infant |
1.5 |
150 |
40 |
50 |
|
2214 |
Neonate |
1.5 |
150 |
40 |
30 |
Use to adjust the shell temperature.
Code |
Specification |
Size |
|
2601 |
Adult |
1.50×0.55m |
|
2602 |
Pediatric |
1.20×0.55m |
|
2603 |
Infant |
1.00×0.55m |
Use after Cardiothoracic surgery, General Surgery and Urinary surgery for surgical drainage.
Model: Simple Straight Connector, Simple Y Connector, Precision Straight Connector, Precision Y Connector